Part # 4532291 Rev 2 (01/15/14) © 2013 Garland Commercial Ranges Limited
INSTALLATION AND
OPERATION MANUAL
GARLAND INDUCTION
BUILT-IN GRIDDLES
with RTCSmp TECHNOLOGY
Real-time Temperature Control System
multi-point sensing
Models:
SHGRIN3500
SHGRIN5000
PLEASE READ ALL SECTIONS OF THIS MANUAL AND
RETAIN FOR FUTURE REFERENCE.
THIS PRODUCT HAS BEEN CERTIFIED AS COMMERCIAL
COOKING EQUIPMENT AND MUST BE INSTALLED BY
PROFESSIONAL PERSONNEL AS SPECIFIED
INSTALLATION AND ELECTRICAL CONNECTION MUST
COMPLY WITH CURRENT CODES:
IN CANADA THE CANADIAN ELECTRICAL CODE PART 1
AND / OR LOCAL CODES.
IN USA THE NATIONAL ELECTRICAL CODE ANSI / NFPA
CURRENT EDITION.
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN CAUSE PROPERTY
DAMAGE, INJURY, OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE INSTRUCTIONS
THOROUGHLY BEFORE INSTALLING OR SERVICING THIS
EQUIPMENT
CE models comply with the latest European
Norms:
EN 60335-1, EN 60335-2-36, EN 62233 (EMC/EMV)
North American models: ETL listed in
compliance with UL 197, CSA C22.2 No.109, NSF-4
Complies with FCC part 18, ICES-001
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY
OF THIS OR ANY OTHER APPLIANCE
CAUTION
A SUITABLE GREASE-COLLECTING MEANS MUST BE
IN PLACE BEFORE OPERATING APPLIANCE
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using only genuine
Garland replacement parts. Garland will have no obligation with respect to any product that has been improperly installed,
adjusted, operated or not maintained in accordance with national and local codes and/or installation instructions provided with
the product or any product that has its serial number defaced, obliterated or removed, and/or which has been modified or
repaired using unauthorized parts or by unauthorized service agents. For a list of authorized service agents and/or genuine
replacement parts, please visit our website at www.garland-group.com for USA and Canada. For international customers, please
visit www.manitowocfoodservice.com. The information contained herein, including design and part specifications, may be
superseded and is subject to change without notice.
Visit our Video Gallery at
www.Garland-Group.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 27 28

Shrnutí obsahu

Strany 1 - OPERATION MANUAL

Part # 4532291 Rev 2 (01/15/14) © 2013 Garland Commercial Ranges Limited INSTALLATION AND OPERATION MANUAL GARLAND INDUCTION BUILT-IN GRID

Strany 2 - CONTACTS

Installation Garland RTCSmp Induction Built-in Griddles 10 Part # 4532291 Rev 2 (01/15/14) • When installing the built-in unit, ensure the i

Strany 3 - CONTENTS

Installation Garland RTCSmp Induction Built-in Griddles Part # 4532291 Rev 2 (01/15/14) 11 The call-outs in the illustrations show: (C) Air

Strany 4 - 1 Safety Requirements

Installation Garland RTCSmp Induction Built-in Griddles 12 Part # 4532291 Rev 2 (01/15/14) Template for Holes and Studs: C. Four (4) we

Strany 5

Installation Garland RTCSmp Induction Built-in Griddles Part # 4532291 Rev 2 (01/15/14) 13 4.5.2.2 Drop-In Mounting Instructions IMPORTANT T

Strany 6 - 2 Components and Features

Installation Garland RTCSmp Induction Built-in Griddles 14 Part # 4532291 Rev 2 (01/15/14) To flush mount the griddle unit: IMPORTANT To pro

Strany 7

Installation Garland RTCSmp Induction Built-in Griddles Part # 4532291 Rev 2 (01/15/14) 15 An example of an Air Intake Kit connected to a buil

Strany 8 - 3.6 Compliances

Installation Garland RTCSmp Induction Built-in Griddles 16 Part # 4532291 Rev 2 (01/15/14) 4.6 Electrical Installation IMPORTANT • Refer to

Strany 9 - 4 Installation

Function Test Garland RTCSmp Induction Built-in Griddles Part # 4532291 Rev 2 (01/15/14) 17 5 Function Test IMPORTANT CAUTION When the unit i

Strany 10 - 4.4 Compartment Protection

Operating Instructions Garland RTCSmp Induction Built-in Griddles 18 Part # 4532291 Rev 2 (01/15/14) 6 Operating Instructions IMPORTANT • I

Strany 11 - 4.5.1 Control Unit

Operating Instructions Garland RTCSmp Induction Built-in Griddles Part # 4532291 Rev 2 (01/15/14) 19 6.3 Considerations • Always season the

Strany 12

Installation and Operation Manual Garland RTCSmp Induction Built-in Griddles 2 Part # 4532291 Rev 2 (01/15/14) WARRANTY Our warranty statements

Strany 13 - IMPORTANT

Cleaning Garland RTCSmp Induction Built-in Griddles 20 Part # 4532291 Rev 2 (01/15/14) 7 Cleaning CAUTION Ensure no liquid can enter into th

Strany 14

Maintenance Garland RTCSmp Induction Built-in Griddles Part # 4532291 Rev 2 (01/15/14) 21 8 Maintenance CAUTION Maintenance and servicing wor

Strany 15

Troubleshooting Garland RTCSmp Induction Built-in Griddles 22 Part # 4532291 Rev 2 (01/15/14) 10 Troubleshooting Do not open the induction

Strany 16 - 4.6 Electrical Installation

Troubleshooting Garland RTCSmp Induction Built-in Griddles Part # 4532291 Rev 2 (01/15/14) 23 10.2 Problems and Possible Causes Problem Poss

Strany 17 - 5 Function Test

Troubleshooting Garland RTCSmp Induction Built-in Griddles 24 Part # 4532291 Rev 2 (01/15/14) 10.3 Troubleshooting with Error Codes (for Ser

Strany 18 - 6 Operating Instructions

Troubleshooting Garland RTCSmp Induction Built-in Griddles Part # 4532291 Rev 2 (01/15/14) 25 NOTES:

Strany 19 - 6.3 Considerations

Troubleshooting Garland RTCSmp Induction Built-in Griddles 26 Part # 4532291 Rev 2 (01/15/14) NOTES:

Strany 20 - 7 Cleaning

Installation and Operation Manual Garland RTCSmp Induction Built-in Griddles Part # 4532291 Rev 2 (01/15/14) Page 27 CORRECT

Strany 21 - 9 Important Rules

Installation & Operation Manual GARLAND INDUCTION BUILT-IN GRIDDLES with RTCSmp TECHNOLOGIES Garland Com

Strany 22 - 10 Troubleshooting

Installation and Operation Manual Garland RTCSmp Induction Built-in Griddles Part # 4532291 Rev 2 (01/15/14) 3 CONTENTS WARRANTY ...

Strany 23

Safety Requirements Garland RTCSmp Induction Built-in Griddles 4 Part # 4532291 Rev 2 (01/15/14) 1 Safety Requirements WARNING This product

Strany 24 - The Unit operates as normal

Safety Requirements Garland RTCSmp Induction Built-in Griddles Part # 4532291 Rev 2 (01/15/14) 5 • The induction unit must only be used for c

Strany 25

Components and Features Garland RTCSmp Induction Built-in Griddles 6 Part # 4532291 Rev 2 (01/15/14) 2 Components and Features 2.1 Applicat

Strany 26

Dimensions and Technical Specifications Garland RTCSmp Induction Built-in Griddles Part # 4532291 Rev 2 (01/15/14) 7 3 Dimensions and Technic

Strany 27

Dimensions and Technical Specifications Garland RTCSmp Induction Built-in Griddles 8 Part # 4532291 Rev 2 (01/15/14) 3.5 Operating Condition

Strany 28

Installation Garland RTCSmp Induction Built-in Griddles Part # 4532291 Rev 2 (01/15/14) 9 4 Installation IMPORTANT • Kitchen designers and i